CBLXW - REPLENISHER, YELLOW, SB-58SY: 22533-0042

  • MSDS: CBLXW
  • Manufacturer: CALCOMP
  • Product Name: REPLENISHER, YELLOW, SB-58SY: 22533-0042
  • National Stock Number: 6750-00N070493
Product Identification

Product ID:REPLENISHER, YELLOW, SB-58SY: 22533-0042
MSDS Date:06/16/1995
FSC:6750
NIIN:00N070493
MSDS Number: CBLXW

Responsible Party
CALCOMP
2411 WEST LA PALMA AVE
ANAHEIM, CA 92801
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 714-821-2556

Cage: IO122

Contractor
CALIFORNIA COMPUTER PRODUCTS SUB OF SANDERS ASSOC
3250 ANAHEIM, CA 92803 US

Telephone: 714-821-2290

Cage: 14668

Ingredients

MINERAL SPIRITS; (MIXED C*8-C*12 ALKANE ISOMERS, N.O.S.)

CAS: 64475-85-0

RTECS: PY8240000

Fraction By Weight: >80%

OSHA PEL N/K

ACGIH TLV: N/K


ACRYLIC POLYMER/RESIN; (ACRYLIC COPOLYMER/RESIN)

CAS: 28430-58-2

Fraction By Weight: <10.0%

OSHA PEL N/K

ACGIH TLV: N/K


PIGMENT YELLOW 83; (YELLOW (PIGMENT)) (MFR'S CAS

CAS: 5567-16-7

Fraction By Weight: <10%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:LD50:(ORAL,RAT) 5 G/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THIS MATERIAL HAS BEEN EXTENSIVELY
TESTED. WHEN USED AS INTENDED, IT DOES NOT REPRESENT ANY KNOWN
HEALTH OR SAFETY HAZARD. EYE:IRRITANT - MAY CAUSE CONJUNCTIVITIS.
SKIN:PROLONGED CONTACT CAUSES DEFATT ING, DRYING, CRACKING,
DERMATITIS. INHALATION:NOT NORMALLY A HAZARD. OVEREXPOSURE MAY
CAUSE HEADACHE, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:NAUSEA & RESPIRATORY IRRITATION.
REPEATED INHALATION EXPOSURE TO RATE OF SIMILAR HYDROCARBON AT
CONCENTRATIONS GREATER THAN OR EQUAL TO 300 PPM IN AIR CAUSED LOW
GRADE (MILD) ANEMIA & KIDNEY EFFECTS. INGEST:NAUSEA & POSSIBLE
GASTRO-INTESTINAL IRRITATION. TARGET ORGANS:EYES, SKIN, RESPIRATORY
SYSTEM.
Medical Cond Aggravated by Exposure:PERS W/PRE-EXISTING HLTH CNDTNS OF
DERM & RESP AILMENTS MAY NOTICE PHYSICAL RXNS WHEN EXPOSED TO SMALL
AMTS OF PROD/VAP. CONSULT THEIR TREATING PHYSICIANS FOR PROPER
ACTION AFTER EXPOSURE.

First Aid

First Aid:EYES:FLUSH W/LG AMTS OF WATER FOR AT LST 15 MINS, OR UNTIL
IRRIT SUBSIDES, INCL UNDER EYELIDS. IF IRRIT PERSISTS, CONT MD.
SKIN:REMOVE CONTAM CLTHG. WASH SKIN THORO W/SOAP & WATER. DO NOT
REUSE CONTAM CLTHG UNTIL SOLVS HAVE BEEN REMOVED. INHAL:MOVE
VICTIM TO FRESH AIR. CALL MD IMMED. IF BRTHG IS IRREG/STOPPED,
START RESUSCITATION IF TRAINED. ADMIN OXYG IF AVAIL. INGEST:DO NOT
INDUCE VOMIT DUE TO A SPIR HAZ. CALL MD.

Fire Fighting

Flash Point Method:TCC
Flash Point:>102F,>39C
Lower Limits:0.8%
Upper Limits:7%
Extinguishing Media:FOAM, DRY CHEMICAL, CO*2 (CARBON DIOXIDE), WATER
FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . AVOID WATER, IT TENDS TO SPREAD HYDROCARBON FIRES.
Unusual Fire/Explosion Hazard:COMBUSTIBLE LIQUID, CAN FORM COMBUSTIBLE
MATERIALS AT OR ABOVE THE FLASHPOINT.

Accidental Release

Spill Release Procedures:REMOVE IGNITION SOURCES. COLLECT ON INERT
ABSORBENT MATERIAL. PLACE IN WASTE CONTAINER APPROVED FOR
COMBUSTIBLE WASTE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:FLAMM LIQ. STORE IN CLSD, COOL, WELL
VENTED AREA, AWAY FROM HEAT & FLAME. READ & FOLLOW LBL PRECS. DO
NOT REUSE CNTNR. DO NOT SMOKE WHEN USING PROD.
Other Precautions:KEEP CNTNRS CLSD WHEN NOT IN USE. MIN BRTHG VAP/MIST.
USE W/ADEQ VENT. AVOID PRLNG/RPTD SKIN CONT. "EMPTY" CNTNRS RETAIN
RESIDUE (LIQ &/OR VAP) & CAN BE DANGEROUS. DISP OF PROPERLY.
MANUFACTURED & BOT TLED FOR USE IN CALCOMP PLOTTERS. EXPOS TO VAPS
& FIRE HAZ SHOULD BE MIN WHEN STORED PROPERLY & USED AS (OTHER
INFO)

Exposure Controls

Respiratory Protection:NOT REQUIRED WHEN USED AS INTENDED. IN
CONCENTRATIONS EXCEEDING RECOMMENDED SAFE EXPOSURE LIMIT, SUCH AS
DURING A MAJOR SPILL, USE A NIOSH/MSHA APPROVED CHEMICAL CARTRIDGE
RESPIRATOR EFFECTIVE FOR ORG ANIC VAPORS.
Ventilation:LOC EXHST; TO MAINTAIN BELOW TLV. NORMAL OFFICE VENT
CONFORMING TO AMERICAN SOCIETY OF HEATING, REFRIGERATING, & AIR
CONDITIONING ENGINEERS (ASHRAE) (SUP DAT)
Protective Gloves:LATEX GLOVES FOR OVEREXP. USE PROT GLOVES, SUCH AS
NITRILE/NEOPRENE, (SUP DAT)
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . WEAR CHEM RESIST APRON WHEN CLEANING
MACHINES AS PRODUCT MAY STAIN CLOTHING.
Work Hygienic Practices:WHENEVER HANDLING CHEMICALS, ALWAYS USE GOOD
PERSONAL HYGIENE PRACTICES, SUCH AS WASHING YOUR HANDS AFTER USING
PRODUCT.
Supplemental Safety and Health
PROT GLOVES: WHEN CONT W/LIQ MAY OCCUR, SUCH AS WHEN PURGING, CLEANING/
HANDLING CONTAINERS.VENT: 1980 STDS IS ADEQ UNDER NORMAL CNDTNS OF
USE. UNDER SOME CNDTNS OF USE/ COMBINATIONS OF EQUIP, OFFICE VENT
MAY NOT BE ADEQ. USERS SHOULD ASSURE THAT VENT IS SUFFICIENT TO
PVNT EXCEEDING EXPOS LIMS. USERS (OTHER INFO)

Chemical Properties

Boiling Pt:B.P. Text:>320F,>160C
Vapor Pres:1 @ 20C
Vapor Density:5
Spec Gravity:0.76 (H*2O=1)
Evaporation Rate & Reference:0.25-0.45 (N-BU AC=1)
Solubility in Water:IMMISCIBLE
Appearance and Odor:YELLOW LIQUID W/SLIGHT PETROLEUM HYDROCARBON ODOR.
Percent Volatiles by Volume:80-100

Stability

Stability Indicator/Materials to Avoid:YES
VERY STRONG OXIDANTS LIKE CHROMIC ACID OR LIQUID CHLORINE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:WASTE TONERS & REPLENISHERS ARE HAZ WASTES AS
DEFINED BY 40 CFR CHAPTER 1 (FLAMMABILITY). TREAT AS HAZ WASTE &
DISP I/A/W ALL APPLIC FED, STATE & LOC DISP REG. DO NOT POUR DOWN
COMMON DRAIN. CONT LICE NSED HAZ WASTE DISP CO/ENVIRON CONTROL
AGENCY FOR ASSISTANCE. EPA WASTE NUMBER:D001.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.